Enterasys Wireless Controller Software CLI Reference Guide 4-101
Parameters
Examples
Thefollowingexamplesetsthepolltimeoutto20seconds
EWC.enterasys.com:ap:defaults:std# poll_timeout 20
4.3.6.8 radio1
Theradio1commandreferstotheradio1context,whichcontainscommandstoconfigureRadio1
oftheWirelessAP.Theradio1commandisaccessiblefromtheap
:defaults:stdcontextoftheCLI.
Thefollowingcommandsareavailableintheap
:defaults:std:radio1context:
adminmode
atpc
beaconp
dcsSeedcsforcommandsintheap:defaults:std:radio1:dcscontext.
divrx
divtx
domain
dtim
frag
hwretries
maxbrate
maxoprate
maxdistance
minbrate
mode
rts
tx_max_power
4.3.6.8.1 admin-mode
Usethiscommenttoconfiguretheadministrationstatusfortheradio.Theadminmodecommand
isaccessiblefromtheap:defaults:std:radio1contextoftheCLI.
Syntax
admin-mode off|on
<value> Specifiestheamountoftime,inseconds,towaitforaresponsefrom
theEnterasysWirelessControllerbeforerebooting.
Note: After you have run the poll_timeout command, you must run the apply command to
implement the change in poll timeout value.