Enterasys RoamAbout Przewodnik Instalacji

Przeglądaj online lub pobierz Przewodnik Instalacji dla Punkty dostępu do sieci WLAN Enterasys RoamAbout. Enterasys RoamAbout Installation guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Wireless Access Point

P/N 9034148-14RoamAboutRBT-4102, RBT-4102-BG, and RBT-4102-EUWireless Access PointInstallation Guide

Strona 2

viiiBetrieb bei Verwendung der 5-GHz-Kanäle in der Europäische Gemeinschaft Der Benutzer/Installierende muss das für das Gerät bereitgestellte Konfigu

Strona 3

ixFrench (FR) Par la présente Enterasys déclare que l'appareil Radio LAN device est conforme aux exigences essentielles et aux autres disposition

Strona 4 - COMPLIANCES

xSAFETY COMPLIANCEPower Cord SafetyPlease read the following safety information carefully before installing the access point:WARNING: Installation and

Strona 5 - RBT-4102-EU

xiImportant! Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against the following:Veuillez

Strona 6 - EC Conformance Declaration

xii• L’appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à la norme IEC 60950. Ces conditions ne sont maintenues que s

Strona 7 - East Communities

xiii• Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein. Die Stromversorgung des Geräts kann nur durch Herausziehen des Geräten

Strona 8 - EC-Konformitätserklärung

xivHAZARDOUS SUBSTANCESThis product complies with the requirements of European Directive, 2002/95/EC, Restriction of Hazardous Substances (RoHS) in El

Strona 9 - Gemeinschaft

xvENTERASYS NETWORKS, INC. LICENSE AGREEMENTBEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,CAREFULLY READ THIS LICENSE AGREEMENT.This document is an

Strona 10

xvi(ii) Incorporate the Program, in whole or in part, in any other product or create derivative works based on the Program, in whole or in part.(iii)

Strona 11

xvii6. DISCLAIMER OF WARRANTY. EXCEPT FOR THOSE WARRANTIES EXPRESSLY PROVIDED TO YOU IN WRITING BY ENTERASYS, ENTERASYS DISCLAIMS ALL WARRANTIES, EITH

Strona 13

xviii9. OWNERSHIP. This is a license agreement and not an agreement for sale. You acknowledge and agree that the Program constitutes trade secrets and

Strona 14

xixTable of ContentsPrefacePurpose...x

Strona 15

xxContentsConsole Port Pin Assignments ...B-3Wiring Map for Serial Cable ...

Strona 16 - (WEEE) NOTICE

xxiPrefacePurposeThis manual provides the specifications and the installation instructions for the RoamAbout RBT-4102, RBT-4102-BG, and the RBT-4102-E

Strona 17

xxiiGetting HelpFor additional support related to this device or document, contact Enterasys Networks using one of the following methods.Before callin

Strona 18

1-1Chapter 1: IntroductionThe RoamAbout RBT-4102, RBT-4102-BG, and the RBT-4102-EU are IEEE 802.11a/b/g access points that provide transparent, wirele

Strona 19

Introduction1-2Package ChecklistThe RoamAbout package includes:• One RoamAbout RBT-4102, RBT-4102-BG, or RBT-4102-EU• One RS-232 console cable• One AC

Strona 20

Hardware Description1-3Rear PanelSecurity SlotConsole PortRJ-45 Port,PoE ConnectorReset ButtonExternal Antenna Connector (802.11b/g Radio)DC Power Sup

Strona 21 - Table of Contents

Introduction1-4Component DescriptionAntennasThe access point includes integrated diversity antennas for wireless communications. A diversity antenna s

Strona 22

Hardware Description1-5Security SlotThe access point includes a Kensington security slot on the rear panel. You can prevent unauthorized removal of th

Strona 23 - Associated Documents

iNOTICEENTERASYS NETWORKS reserves the right to make changes in specifications and other information contained in this document and its web site witho

Strona 24 - Getting Help

Introduction1-6Reset ButtonThis button is used to reset the access point or restore the factory default configuration. If you hold down the button for

Strona 25 - Chapter 1: Introduction

2-1Chapter 2: Hardware InstallationTo install the access point, follow the steps outlined below:1. Select a Site – Choose a proper place for the acces

Strona 26 - Hardware Description

Hardware Installation2-2• Using the mounting bracket, mark the position of the four screw holes on the wall or ceiling. For concrete or brick walls, y

Strona 27

Hardware Installation2-33. Lock the Access Point in Place – To prevent unauthorized removal of the access point, you can use a Kensington Slim MicroSa

Strona 28 - Component Description

Hardware Installation2-4

Strona 29 - Ethernet Port

3-1Chapter 3: Access Point ConfigurationThis chapter describes how to use the Web interface to perform initial configuration of the access point.You c

Strona 30 - Power Connector

Access Point Configuration3-2• Set the emulation mode to VT100.• When using HyperTerminal, select Terminal keys, not Windows keys.Note: When using H

Strona 31

Using the CLI3-3a. Enter country ? to display the list of countries. b. Determine the code for your country, and then enter country followed by your c

Strona 32 - Hardware Installation

Access Point Configuration3-4c. Enter no ip dhcp to disable DHCP.d. Set the IP Address. Enter ip address ip-address netmask gateway, where ip-address

Strona 33

Using the CLI3-55. Specify the management VLAN ID for the access point:The management VLAN is for managing the access point. For example, the access p

Strona 34

iiCOMPLIANCESRBT-4102Federal Communication Commission Interference StatementThis equipment has been tested and found to comply with the limits for a C

Strona 35 - Using the CLI

Access Point Configuration3-6Using Web ManagementNotes: • The default username is admin, and the default password is password.• To get help, click o

Strona 36 - Logging In

Using Web Management3-73. If applicable, set the Country Code:a. Click the arrow in the Country pull-down menu to select the appropriate country, then

Strona 37

Access Point Configuration3-8c. Click the Reset button next to Reset Access Point, located at the bottom of the page.The access point prompts you to c

Strona 38 - Access Point Configuration

Using Web Management3-94. Enter the following information, and click Apply.• System Name is an alias used for the access point, enabling the device t

Strona 39

Access Point Configuration3-10b. Click the DHCP Client: Disable radio button. DHCP allows you to enable or disable the option to obtain the IP setting

Strona 40 - Using Web Management

Using Web Management3-11If you have management stations, DNS, RADIUS, or other network servers located on another subnet, type the IP address of the d

Strona 41

Access Point Configuration3-126. To change the username and password.a. Click Administration from the menu on the left hand side of the page.The Admin

Strona 42

Using Web Management3-137. To specify the management VLAN ID:a. Click Filter Control from the menu.The Filter Control page appears.b. Click the Manage

Strona 43

Access Point Configuration3-14

Strona 44

4-1Chapter 4: Network Configuration Wireless networks support a standalone configuration as well as an integrated configuration with 10/100 Mbps Ether

Strona 45

iiiWireless 4.9 GHz Band Statement:Installation and operation requires an approved license from the FCC.Industry Canada - Class BThis digital apparatu

Strona 46

Network Configuration4-2Network TopologiesAd Hoc Wireless LAN (no Access Point)An ad hoc wireless LAN consists of a group of computers, each equipped

Strona 47

Network Topologies4-3Infrastructure Wireless LANThe access point also provides access to a wired LAN for wireless workstations. An integrated wired/wi

Strona 48

Network Configuration4-4Infrastructure Wireless LAN for Roaming Wireless PCsThe Basic Service Set (BSS) defines the communications domain for each acc

Strona 49

Network Topologies4-5Infrastructure Wireless BridgeThe IEEE 802.11 standard defines a Wireless Distribution System (WDS) for bridge connections betwee

Strona 50 - Network Topologies

Network Configuration4-6

Strona 51 - Infrastructure Wireless LAN

A-1Appendix A: TroubleshootingDiagnosing Access Point IndicatorsTroubleshooting ChartSymptom ActionPower LED is Off• AC power adapter may be disconnec

Strona 53

B-1Appendix B: Cables and PinoutsTwisted-Pair Cable Assignments For 10/100BASE-TX connections, a twisted-pair cable must have two pairs of wires. Each

Strona 54

Cables and PinoutsB-2Straight-Through WiringIf the twisted-pair cable is to join two ports and only one of the ports has an internal crossover (MDI-X)

Strona 55 - Appendix A: Troubleshooting

Console Port Pin AssignmentsB-3Crossover WiringIf the twisted-pair cable is to join two ports and either both ports are labeled with an “X” (MDI-X) or

Strona 56 - Troubleshooting

ivEC Conformance Declaration Marking by the above symbol indicates compliance with the Essential Requirements of the R&TTE Directive of the Europe

Strona 57 - 10/100BASE-TX Pin Assignments

Cables and PinoutsB-4Wiring Map for Serial Cable Table B-1. 10/100BASE-TX MDI and MDI-X Port PinoutsSwitch’s 9-Pin Serial Port Null Modem PC’s 9-Pin

Strona 58 - Straight-Through Wiring

C-1Appendix C: SpecificationsGeneral SpecificationsMaximum Channels802.11aRBT-4102US & Canada: 13 (normal mode), 5 (turbo mode)RBT-4102-EUETSI: 19

Strona 59 - Console Port Pin Assignments

SpecificationsC-2Modulation Type802.11a: BPSK, QPSK, 16-QAM, 64-QAM802.11g: CCK, BPSK, QPSK, OFDM802.11b: CCK, BPSK, QPSKNetwork ConfigurationInfrastr

Strona 60 - Wiring Map for Serial Cable

General SpecificationsC-3Weight0.687 kg (1.514 lbs)LED IndicatorsPower, Ethernet Link/Activity, 11a and 11g Wireless Link/ActivityNetwork ManagementWe

Strona 61 - Appendix C: Specifications

SpecificationsC-4CompliancesRBT-4102FCC Class B (US)ICES-003 (Canada)RBT-4102-EURTTED 1999/5/ECARB STD-T70, ARB STD-66, RCR STD-33, ARB STD-T71 (Japan

Strona 62 - Specifications

SensitivityC-5SensitivityIEEE 802.11a Sensitivity (GHz - dBm)Modulation/Rates 5.15-5.250 5.25-5.350 5.50-5.700 5.725-5.825BPSK (6 Mbps) -88 -88 -88 -8

Strona 63 - General Specifications

SpecificationsC-6Transmit Power IEEE 802.11a Maximum Output Power (GHz - dBm)Data Rate 5.15-5.250 5.25-5.350 5.50-5.700 5.725-5.8256 Mbps 20 20 20 199

Strona 64 - Compliances

Operating RangeC-7Operating RangeNote: The operating range distances listed in the following tables are for typical environments only. Operating range

Strona 65 - Sensitivity

SpecificationsC-8External AntennasThe RBT-4102 has been certified by the FCC, for use in the United States, to operate with these antennas:Note: High

Strona 66 - Transmit Power

External AntennasC-9For information on the external antennas supported by the access point, refer to the RoamAbout RBT-4102 / RBT-1602 Wireless Access

Strona 67 - Operating Range

vOperation Using 5 GHz Channels in the European CommunityThe user/installer must use the provided configuration utility to check the current channel o

Strona 69

Index-1Aadditional documentation xxiantennas, positioning 2-3associated documentsxxiBBasic Service Set See BSSBSS 4-3Ccableassignments B-1change user

Strona 70

IndexIndex-2LLED indicators 1-4lock, Kensington 2-2, 2-3Mmounting bracket 2-2mounting the access point 2-1Nnetwork topologiesinfrastructure 4-3infrast

Strona 71

vitemporary interruption of operation of this device. The radar detection feature will automatically restart operation on a channel free of radar.• Th

Strona 72

viiBetriebsländer und Bedingungen für die Verwendung in der Europäischen Gemeinschaft Dieses Gerät ist für den Betrieb in allen Ländern der Europäisch

Komentarze do niniejszej Instrukcji