Port Configuration Command Set
Setting Speed and Duplex Mode
SecureStack B2 Configuration Guide 3-19
3.3.3.4 set port duplex
Use this command to set the default duplex type for one or more ports.
set port duplex port-string {full | half}
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows how to set Fast Ethernet port 17 in unit 1 to full duplex:
NOTE: This command will only take effect on ports that have auto-negotiation disabled.
port-string Specifies the port(s) for which duplex type will be set. For a
detailed description of possible port-string values, refer to
Section 3.1.1.
full | half Sets the port(s) to full-duplex or half-duplex operation.
B2(rw)->set port duplex fe.1.17 full