Logging And Network Management Command Set
Configuring System Logging
SecureStack B2 Configuration Guide 10-5
Command Defaults
If ip- addr is not specified, an entry in the Syslog server table will be created
with the specified index number and the system loopback address, 127.0.0.1,
will be used.
If not specified, facility, severity and port will be set to defaults configured
with the se t lo g g ing de fault command (Section 10.2.1.5).
If state is not specified, the server will not be enabled or disabled.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This command shows how to enable a Syslog server configuration for index 1, IP address
134.141.89.113, facility local4, severity level 3 on port 514:
B2(rw)->set logging server 1 ip-addr 134.141.89.113 facility local4 severity 3
port 514 state enable