Enterasys SecureStack A2 A2H124-48P Dokumentacja Strona 292

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 634
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 291
SNMP Configuration Command Set
Configuring SNMP Notification Parameters
4-58 SecureStack A2 Configuration Guide
4.3.7.8 set snmp notifyprofile
Use this command to create an SNMP notify filter profile configuration. This associates a
notification filter, created with the set snmp notifyfilter command (Section 4.3.7.5), to a set of
SNMP target parameters to determine which management targets should not receive SNMP
notifications.
set snmp notifyprofile profile targetparam targetparam [volatile | nonvolatile]
Syntax Description
Command Defaults
If storage type is not specified, nonvolatile (permanent) will be applied.
Command Mode
Read-Write.
Example
This example shows how to create an SNMP notify profile named area51
and associate a target
parameters entry.
profile Specifies an SNMP filter notify name.
targetparam
targetparam
Specifies an associated entry in the SNMP Target Params
Table.
volatile |
nonvolatile
(Optional) Specifies a storage type.
A2(rw)->set snmp notifyprofile area51 targetparam v3ExampleParams