Enterasys SecureStack A2 A2H124-48P Dokumentacja Strona 551

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 634
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 550
Logging And Network Management Command Set
Configuring System Logging
SecureStack A2 Configuration Guide 11-5
Command Defaults
If ip-addr is not specified, an entry in the Syslog server table will be created
with the specified index number and the system loopback address, 127.0.0.1,
will be used.
If not specified, facility, severity and port will be set to defaults configured
with the set logging default command (Section 11.2.1.5).
If state is not specified, the server will not be enabled or disabled.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This command shows how to enable a Syslog server configuration for index 1, IP address
134.141.89.113, facility local4, severity level 3 on port 514:
A2(rw)->set logging server 1 ip-addr 134.141.89.113 facility local4 severity 3
port 514 state enable
Przeglądanie stron 550
1 2 ... 546 547 548 549 550 551 552 553 554 555 556 ... 633 634

Komentarze do niniejszej Instrukcji

Brak uwag