clear spantree spanguardtimeout
9-28 Spanning Tree Configuration
clear spantree spanguardtimeout
UsethiscommandtoresettheSpanningTreeSpanGuardtimeouttothedefaultvalueof300
seconds.
Syntax
clear spantree spanguardtimeout
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresettheSpanGuardtimeoutto300seconds:
B2(rw)->clear spantree spanguardtimeout
show spantree spanguardlock
UsethiscommandtodisplaytheSpanGuardlockstatusofoneormoreports.
Syntax
show spantree spanguardlock [port-string]
Parameters
Defaults
Ifnoportstringisspecified,theS panGuardlockstatusforallportsisdisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaytheSpanGuardlock statusforfe.1.1:
B2(su)->show spantree spanguardlock fe.1.1
Port fe.1.1 is Unlocked
portstring (Optional)Specifiestheport(s)forwhichtoshowSpanGuardlockstatus.
Foradetaileddescriptionofpossibleportstringvalues,refertoPortString
SyntaxUsedintheCLIonpage 72.